1,500 VA Elevator UPS
Line Interactive UPS

1,500 VA Elevator UPS

ELSIPOWER 1,500 VA elevator UPS (elevator rescue UPS): during a power cut it supplies the energy needed to bring the car to the nearest floor, so passengers are not trapped. Suitable for 5.5 kW, 7.5 kW and 11 kW elevator motors, with peak-current software, cold start and automatic shutdown after rescue.

  • Purpose-built for elevator rescue applications (elevator rescue UPS)
  • Microprocessor-controlled digital control and LED status panel
  • Automatic voltage regulation (AVR)
  • Wide input voltage range: 170–280 V

The quote button opens your e-mail app addressed to elsi@elsi.com.tr · 0212 210 75 51

  • 24/7 technical service
Highlights

Product features

  • Purpose-built for elevator rescue applications (elevator rescue UPS)
  • Microprocessor-controlled digital control and LED status panel
  • Automatic voltage regulation (AVR)
  • Wide input voltage range: 170–280 V
  • Special software for elevator motor peak currents
  • Automatic shutdown 7 minutes after the rescue operation
  • Cold Start (start-up from battery without mains)
  • Automatic fuse and audible alarm system
  • Simulated sine wave output
  • Smart battery control and deep discharge protection
  • Input and output cables ready for elevator connection
  • Optional RS232 / USB communication and LCD display
Where is it used?

Applications

  • Apartment and residential elevators
  • Residential complex elevators
  • Business center and office tower elevators
  • Office building elevators
  • Hotel elevators
  • Shopping mall elevators
  • Hospital and clinic elevators
  • School and public building elevators
  • Elevator emergency rescue systems
  • Elevator installation and maintenance companies
Technical information

Technical specifications

Model1,500 Elevator
Capacity1,500 VA / 900 W
Suitable elevator motor power5.5 kW / 7.5 kW / 11 kW
PhaseSingle-phase input / single-phase output (line interactive)
Input voltage220 VAC (116 – 276 VAC)
Input frequency50 Hz ±10%
Output voltage (battery mode)220 VAC ±10%
Output frequency (battery mode)50 Hz ±1%
WaveformSine wave (mains) / modified sine wave (battery mode)
Transfer time< 10 ms
Output sockets4
Crest factor3:1
Battery typeSealed maintenance-free dry type
Recharge time90% capacity in 8 hours
Battery protectionOvercharge and deep discharge protection
Rescue operations5.5 kW: 5 times / 7.5 kW: 4 times / 11 kW: 2 times (depends on motor power and operating conditions)
Automatic shutdown7 minutes after rescue
Cold StartYes
LED indicatorsGreen mains / Yellow battery / Red UPS fault
AlarmsAudible warning for battery mode, low battery and overload
Short circuit protectionAC fuse + electronic on mains, electronic on battery
Surge protectionRJ11 & RJ45 (optional)
CommunicationRS232 & USB (optional)
TransformerE type
Operating temperature0 – 40 °C
Humidity20% – 90% (non-condensing)
Noise (1 m)< 45 dB
StandardsCE, EN 62040-1 (LVD), EN 62040-2 (EMC)
Dimensions (W x D x H)136 x 328 x 186 mm
Net weight10.2 kg
Warranty2 years
Guide

What is an elevator UPS?

An elevator UPS supplies the energy the elevator needs to run its rescue sequence during a power cut, helping bring the car to the nearest floor.

The ELSIPOWER 1,500 VA elevator UPS is designed for this job with peak-current software, cold start and automatic shutdown 7 minutes after rescue.

  • Energy for elevator rescue during outages
  • Software for motor peak currents
  • Cold start from battery
  • Automatic shutdown after rescue
Selection

How to choose an elevator UPS

Motor power and the number of rescues needed decide the choice: 5 rescues at 5.5 kW, 4 at 7.5 kW and 2 at 11 kW (varies with conditions).

The UPS must be compatible with the elevator controller and rescue logic, so install it together with your elevator company and keep batteries checked.

FAQ

Elevator UPS FAQ

What does an elevator UPS do?

It powers the rescue system during an outage so the car can reach the nearest floor.

Elevator rescue UPS vs standard UPS?

It handles motor inrush currents, starts from battery without mains and shuts down after rescue — features a standard PC UPS lacks.

How many rescues can it perform?

5 rescues at 5.5 kW, 4 at 7.5 kW and 2 at 11 kW; actual numbers depend on conditions.

Which elevators can it be used with?

Residential, office, hotel, mall and hospital elevators; check controller compatibility first.

When should the battery be replaced?

Sealed batteries usually last 3–5 years; test them yearly.

Is there a warranty?

Yes, a 2-year product warranty.

Get a quotation

Request a quote for 1,500 VA Elevator UPS

Tell us your power requirement and quantity; our engineers will recommend the right configuration and send your quotation the same day.

Contact us with Whatsapp