1,500 VA Elevator UPS
Line Interactive UPS

1,500 VA Elevator UPS

ELSIPOWER 1,500 VA elevator UPS (elevator rescue UPS): during a power cut it supplies the energy needed to bring the car to the nearest floor, so passengers are not trapped. Suitable for 5.5 kW, 7.5 kW and 11 kW elevator motors, with peak-current software, cold start and automatic shutdown after rescue.

  • Purpose-built for elevator rescue applications (elevator rescue UPS)
  • Microprocessor-controlled digital control and LED status panel
  • Automatic voltage regulation (AVR)
  • Wide input voltage range: 170–280 V

The quote button opens your e-mail app addressed to elsi@elsi.com.tr · 0212 210 75 51

  • Installation across Türkiye
  • 24/7 technical service
  • Since 1978
Highlights

Product features

  • Purpose-built for elevator rescue applications (elevator rescue UPS)
  • Microprocessor-controlled digital control and LED status panel
  • Automatic voltage regulation (AVR)
  • Wide input voltage range: 170–280 V
  • Special software for elevator motor peak currents
  • Automatic shutdown 7 minutes after the rescue operation
  • Cold Start (start-up from battery without mains)
  • Automatic fuse and audible alarm system
  • Simulated sine wave output
  • Smart battery control and deep discharge protection
  • Input and output cables ready for elevator connection
  • Optional RS232 / USB communication and LCD display
Where is it used?

Applications

  • Apartment and residential elevators
  • Residential complex elevators
  • Business center and office tower elevators
  • Office building elevators
  • Hotel elevators
  • Shopping mall elevators
  • Hospital and clinic elevators
  • School and public building elevators
  • Elevator emergency rescue systems
  • Elevator installation and maintenance companies
Technical information

Technical specifications

Model1,500 Elevator
Capacity1,500 VA / 900 W
Suitable elevator motor power5.5 kW / 7.5 kW / 11 kW
PhaseSingle-phase input / single-phase output (line interactive)
Input voltage220 VAC (116 – 276 VAC)
Input frequency50 Hz ±10%
Output voltage (battery mode)220 VAC ±10%
Output frequency (battery mode)50 Hz ±1%
WaveformSine wave (mains) / modified sine wave (battery mode)
Transfer time< 10 ms
Output sockets4
Crest factor3:1
Battery typeSealed maintenance-free dry type
Recharge time90% capacity in 8 hours
Battery protectionOvercharge and deep discharge protection
Rescue operations5.5 kW: 5 times / 7.5 kW: 4 times / 11 kW: 2 times (depends on motor power and operating conditions)
Automatic shutdown7 minutes after rescue
Cold StartYes
LED indicatorsGreen mains / Yellow battery / Red UPS fault
AlarmsAudible warning for battery mode, low battery and overload
Short circuit protectionAC fuse + electronic on mains, electronic on battery
Surge protectionRJ11 & RJ45 (optional)
CommunicationRS232 & USB (optional)
TransformerE type
Operating temperature0 – 40 °C
Humidity20% – 90% (non-condensing)
Noise (1 m)< 45 dB
StandardsCE, EN 62040-1 (LVD), EN 62040-2 (EMC)
Dimensions (W x D x H)136 x 328 x 186 mm
Net weight10.2 kg
Warranty2 years
Get a quotation

Request a quote for 1,500 VA Elevator UPS

Tell us your power requirement and quantity; our engineers will recommend the right configuration and send your quotation the same day.

Contact us with Whatsapp