Line Interactive UPS
1,500 VA Elevator UPS
ELSIPOWER 1,500 VA elevator UPS (elevator rescue UPS): during a power cut it supplies the energy needed to bring the car to the nearest floor, so passengers are not trapped. Suitable for 5.5 kW, 7.5 kW and 11 kW elevator motors, with peak-current software, cold start and automatic shutdown after rescue.
- Purpose-built for elevator rescue applications (elevator rescue UPS)
- Microprocessor-controlled digital control and LED status panel
- Automatic voltage regulation (AVR)
- Wide input voltage range: 170–280 V
The quote button opens your e-mail app addressed to elsi@elsi.com.tr · 0212 210 75 51
- Installation across Türkiye
- 24/7 technical service
- Since 1978
Highlights
Product features
- Purpose-built for elevator rescue applications (elevator rescue UPS)
- Microprocessor-controlled digital control and LED status panel
- Automatic voltage regulation (AVR)
- Wide input voltage range: 170–280 V
- Special software for elevator motor peak currents
- Automatic shutdown 7 minutes after the rescue operation
- Cold Start (start-up from battery without mains)
- Automatic fuse and audible alarm system
- Simulated sine wave output
- Smart battery control and deep discharge protection
- Input and output cables ready for elevator connection
- Optional RS232 / USB communication and LCD display
Where is it used?
Applications
- Apartment and residential elevators
- Residential complex elevators
- Business center and office tower elevators
- Office building elevators
- Hotel elevators
- Shopping mall elevators
- Hospital and clinic elevators
- School and public building elevators
- Elevator emergency rescue systems
- Elevator installation and maintenance companies
Technical information
Technical specifications
| Model | 1,500 Elevator |
|---|---|
| Capacity | 1,500 VA / 900 W |
| Suitable elevator motor power | 5.5 kW / 7.5 kW / 11 kW |
| Phase | Single-phase input / single-phase output (line interactive) |
| Input voltage | 220 VAC (116 – 276 VAC) |
| Input frequency | 50 Hz ±10% |
| Output voltage (battery mode) | 220 VAC ±10% |
| Output frequency (battery mode) | 50 Hz ±1% |
| Waveform | Sine wave (mains) / modified sine wave (battery mode) |
| Transfer time | < 10 ms |
| Output sockets | 4 |
| Crest factor | 3:1 |
| Battery type | Sealed maintenance-free dry type |
| Recharge time | 90% capacity in 8 hours |
| Battery protection | Overcharge and deep discharge protection |
| Rescue operations | 5.5 kW: 5 times / 7.5 kW: 4 times / 11 kW: 2 times (depends on motor power and operating conditions) |
| Automatic shutdown | 7 minutes after rescue |
| Cold Start | Yes |
| LED indicators | Green mains / Yellow battery / Red UPS fault |
| Alarms | Audible warning for battery mode, low battery and overload |
| Short circuit protection | AC fuse + electronic on mains, electronic on battery |
| Surge protection | RJ11 & RJ45 (optional) |
| Communication | RS232 & USB (optional) |
| Transformer | E type |
| Operating temperature | 0 – 40 °C |
| Humidity | 20% – 90% (non-condensing) |
| Noise (1 m) | < 45 dB |
| Standards | CE, EN 62040-1 (LVD), EN 62040-2 (EMC) |
| Dimensions (W x D x H) | 136 x 328 x 186 mm |
| Net weight | 10.2 kg |
| Warranty | 2 years |