1 kVA Online UPS (Single-Phase)
Single-Phase In / Single-Phase Out Online UPS

1 kVA Online UPS (Single-Phase)

ELSIPOWER 1 kVA online UPS: single-phase input / single-phase output, 1 kVA / 0.9 kW output. Double-conversion technology delivers clean, regulated, uninterrupted power for servers, network cabinets, medical devices and POS systems, with 0 ms transfer to battery during outages.

  • High Frequency True Double-Conversion Technology
  • DSP (Digital Signal Processors) Technology
  • Input Power Factor Correction (PFC)
  • Wide Input Voltage Range (110~300V)

The quote button opens your e-mail app addressed to elsi@elsi.com.tr · 0212 210 75 51

  • Installation across Türkiye
  • 24/7 technical service
  • Since 1978
Highlights

Product features

  • High Frequency True Double-Conversion Technology
  • DSP (Digital Signal Processors) Technology
  • Input Power Factor Correction (PFC)
  • Wide Input Voltage Range (110~300V)
  • Output Power Factor = 0.9 (1-2-3 kVA)
  • Cold Start (Battery Startup Without Utility Power)
  • Automatic Frequency Detection
  • ECO Mode for High Energy Efficiency
  • Selectable Output Voltage via LCD Display
  • 50Hz / 60Hz Frequency Converter Mode
  • Self-Test Function at Startup
  • Advanced Battery Management (ABM)
  • Short Circuit and Overload Protection
  • Automatic Battery Charging in Off Mode
  • Load Sensitive Smart Fan Control
  • Excellent Generator Compatibility
  • Standard RS232 Communication Port
  • USB / SNMP Communication Port (Optional)
  • Emergency Power Off (EPO) Function (Optional)
  • Expandable Battery Unit with Additional Charger Card (Optional)
  • Electromagnetic Compatibility, EMC – LVD CE Certifications
Where is it used?

Applications

  • Server and network systems
  • Security camera and alarm systems
  • Office computers and workstations
  • Data storage and communication devices
  • Medical and laboratory equipment
  • Telecommunication systems
  • Industrial automation applications
  • Banking and financial systems
Technical information

Technical specifications

Capacity1,000 VA / 900 W
Phase configurationSingle-phase in / out
TechnologyOnline double conversion
Input voltage208 / 220 / 230 / 240 VAC
Input voltage range176 – 280 VAC (no derating); 110 – 176 / 280 – 300 VAC with derating
Input frequency40 – 70 Hz (auto sensing)
Input power factor≥ 0.98
Bypass voltage range−25% ~ +15% (selectable)
Output voltage208 / 220 / 230 / 240 VAC (selectable)
Voltage regulation± 1%
Output frequency45 – 55 / 55 – 65 Hz (synchronised); 50 / 60 Hz ± 0.1 Hz on battery
Waveform / output PFPure sine / 0.9
Crest factor3:1
Harmonic distortion≤ 2% linear, ≤ 5% non-linear
Transfer time0 ms mains to battery; 4 ms inverter to bypass (typical)
Overload capacity105–125%: 1 min; 125–150%: 30 s; >150%: 300 ms (bypass)
Charge current1 A (standard), 6 A (long-run L model)
Recharge time90% in 8 hours
Operating temp. / humidity / IP0 – 40 °C / 20 – 90% / IP20
Noise (1 m)≤ 50 dB
CommunicationRS232 / USB (optional), SNMP (optional)
StandardsSafety: IEC/EN 62040-1, IEC 62477-1; EMC: IEC/EN 62040-2, IEC 61000-4-2/3/4/5/6/8
Efficiency (mains / battery / ECO)≥ 90% / ≥ 85% / ≥ 95%
Dimensions (WxDxH)144 x 312 x 216 mm (S) / 144 x 336 x 216 mm (L)
Net weight11 kg (S) / 6 kg (L)
Get a quotation

Request a quote for 1 kVA Online UPS (Single-Phase)

Tell us your power requirement and quantity; our engineers will recommend the right configuration and send your quotation the same day.

Contact us with Whatsapp